cubic scintillator test
Purpose
Checking the operation of the cubic scintillator
It was in 446, not used for months.
Setup
cubic scintillator
placed in the blackbox
HV supplied by CAEN HV power supply
-1000 V (ch 0)
DAQ - Oscilloscope
PMT output is directly connected to the oscilloscope
trigger level: -176 mV
a signal
width ~ 25 ns
height ~ 400 mV
Muon signal?
When HV is less than 700 V, no signal observed.
Signal rate looks high. Is it normal?